/

Partial Discharge Testing Certification Pathway

Partial Discharge Testing Certification Pathway

Learn how to detect, diagnose, and interpret Partial Discharge in real MV and HV assets - switchgear, transformers, cables, and rotating machines- taught by working PD engineers from a UK-based leader in asset monitoring.

partial discharge testing course thumbnail

Launching Soon

Launch Date

Advanced

Skill Level

Get Certified

Lifetime Validity

7

Days

No Questions Refund Policy

About this course

Partial Discharge is the earliest warning that insulation is starting to fail in MV and HV assets. Miss it, and it moves quietly toward breakdown, equipment damage, safety incidents, and unplanned outages.

Most engineers know PD matters. What's missing is a structured way to learn how it actually works — how it starts, how it's detected, and how test results turn into maintenance decisions. That knowledge lives inside a few specialist teams, not in a course you can follow end to end.

This Level 1 and Level 2 pathway is that structured route: from how PD forms, through online and offline testing and sensor technologies, to asset-specific diagnostics on switchgear, transformers, cables, and rotating machines — with real case studies throughout. Both levels include an online exam and CPD points on completion, delivered by working PD engineers from Monitra (formerly HVPD).

Industry Collaborators

monitra logo partial discharge course

Monitra

Monitra is a specialist MV/HV asset monitoring company focused on improving the safety, reliability, and uptime of high-voltage electrical networks. Formerly known as HVPD, Monitra develops Partial Discharge testing and monitoring solutions for assets such as cables, switchgear, transformers, generators, and motors.

Skills you'll learn

PD Fundamentals

Understand what Partial Discharge is, why it starts in and around insulation, and why it's an early indicator of failure.

PD Location in Real Assets

Identify where PD occurs across switchgear, transformers, MV/HV cables, joints, terminations, and rotating machines.

Online vs Offline Testing

Select the right method for the situation and see how each supports condition-based maintenance.

Sensors & Measurement

Understand how HFCT, TEV, acoustic, UHF, and coupling-capacitor methods detect different PD signals.

Reading PD Data

Interpret PD magnitude, pulse count, PRPD patterns, and trends to judge asset condition and risk.

Field Decision-Making

Apply PD results to maintenance planning, fault prevention, asset-life extension, and safer HV operation.

TOPICS

Partial Discharge Testing

Online PD Testing

Offline PD Testing

PD Sensors

PD in Switchgears

Who should join

1

New to PD

Engineers who want to understand PD basics, detection methods, & insulation failure risks

2

MV/HV Asset Engineer

Professionals working with switchgear, transformers, cables, motors, or substations

3

Testing/Maintenance

Teams for condition monitoring, diagnostics, outage prevention, & maintenance planning

Syllabus

7

modules

6h 30m

total length

Level 1 - M1 - Foundations of PD Testing
7

lectures

75

m

Build the core mental model: what PD is, why it matters, and where it shows up across every major asset type.

Introduction to Monitra

Benefits of PD testing

PD detection theory

PD detection in power cables

PD detection in switchgear and transformers

PD detection in rotating machines

Real-world case studies

Module PPT

Module Quiz

Level 1 - M1 - Foundations of PD Testing
7

lectures

75

m

Build the core mental model: what PD is, why it matters, and where it shows up across every major asset type.

Introduction to Monitra

Benefits of PD testing

PD detection theory

PD detection in power cables

PD detection in switchgear and transformers

PD detection in rotating machines

Real-world case studies

Module PPT

Module Quiz

Level 1 - M2 - Overview of Online PD Testing
5

lectures

60

m

Level 1 - M2 - Overview of Online PD Testing
5

lectures

60

m

Level 1 - M3 - Overview of Offline PD Testing
4

lectures

40

m

Level 1 - M3 - Overview of Offline PD Testing
4

lectures

40

m

Level 2 - M1 - PD Testing in Cables
6

lectures

55

m

Level 2 - M1 - PD Testing in Cables
6

lectures

55

m

Level 2 - M2 - PD Testing in Switchgear
3

lectures

50

m

Level 2 - M2 - PD Testing in Switchgear
3

lectures

50

m

Level 2 - M3 - PD Testing in Transformers
3

lectures

40

m

Level 2 - M3 - PD Testing in Transformers
3

lectures

40

m

Level 2 - M4 - PD Testing in Rotating Machines
6

lectures

70

m

Level 2 - M4 - PD Testing in Rotating Machines
6

lectures

70

m

Course Accreditation

cpd accrediation partial discharge course

Verified Course

CPD Accredited by The CPD Standards Office

This pathway is formally accredited by The CPD Standards Office (CPD Provider No. 21330), so the points you earn are independently recognised — not self-issued. Complete Level 1 to earn 3.5 CPD points and Level 2 for a further 5 CPD points, awarded on passing each level’s online examination. Many engineering bodies and employers use CPD points to evidence ongoing professional development, which makes them useful at appraisals, for professional-body membership, and as clear proof that your MV/HV skills are current.

VALIDATE YOUR SKILL

Certificate of Completion

Practical First

Portfolio Friendly

Never Expires

Background Image of all the Course Certificates

COURSE CERTIFICATE

COURSE CERTIFICATE

COURSE CERTIFICATE

Partial Discharge Testing Certification Pathway

Partial Discharge Testing Certification Pathway

Partial Discharge Testing Certification Pathway

ISSUED TO

ISSUED TO

ISSUED TO

Mr. Rushabh Koradia

Mr. Rushabh Koradia

Mr. Rushabh Koradia

Date:

Date:

Date:

Duration:

Duration:

Duration:

6h 30m
6h 30m
6h 30m

Certificate ID:

Certificate ID:

Certificate ID:

TEGA26-0022

TEGA26-0022

TEGA26-0022

Gaurav Joshi

Gaurav Joshi

Gaurav Joshi

Founder, TEGA

Founder, TEGA

Founder, TEGA

*Demo certificate - not a valid credential.

Instructor Details

course instrcutor -Malcolm Seltzer-Grant

Instructor

Malcolm Seltzer-Grant

Technical Director, Monitra

Malcolm Seltzer-Grant received a BEng (Hons) degree in electrical and electronic engineering from The University of Manchester in 2005. He then joined HVPD (now Monitra) whilst studying for a PhD degree at The University of Manchester School of Electrical and Electronic Engineering which was awarded in 2010 for research into measurement techniques and applications of on-line partial discharge detection in power cables. At Monitra Malcolm has held several roles in test services and product development, since 2016 he has been in his present role as Technical Director. He has worked extensively in the field performing PD measurements and other high voltage tests on a range of high voltage assets including power cables, switchgear, transformers and rotating machines. He has led several development projects with internal and external funding that have formed the foundation of Monitra’s technology. He has co-authored several journal papers and presented conference papers at CIGRE, IEEE IAS and IEEE DEIS events sharing knowledge and experiences in the PD field.

partial discharge testing course thumbnail

Partial Discharge Testing Certification Pathway

Launching Soon

What you will get:

On-demand modules

Certificate of completion

7-day risk free investment

Job ready skills

Lifetime Validity

4.5

/5

Loved By 1000+ Engineers in 45+ Countries

FREE ACCESS

Bonus Resources to Grow Fast

  • partial discharge testing bonus 1

    Bonus Resource #1

    Online vs Offline PD Testing

    Know which method to use and when, with field-ready "choose this when" cards.

    partial discharge testing bonus 1

    Bonus Resource #1

    Online vs Offline PD Testing

    Know which method to use and when, with field-ready "choose this when" cards.

  • partial discharge testing bonus 2

    Bonus Resource #2

    Sensor Selection & PRPD Interpretation Guide

    Pick the right sensor per asset and read the pattern with confidence.

    partial discharge testing bonus 2

    Bonus Resource #2

    Sensor Selection & PRPD Interpretation Guide

    Pick the right sensor per asset and read the pattern with confidence.

  • partial discharge testing bonus 3

    Bonus Resource #3

    Real-World Case Study Pack

    See PD testing on live assets: real detections, diagnoses, and the calls engineers made.

    partial discharge testing bonus 3

    Bonus Resource #3

    Real-World Case Study Pack

    See PD testing on live assets: real detections, diagnoses, and the calls engineers made.

  • partial discharge testing bonus 1

    Bonus Resource #1

    Online vs Offline PD Testing

    Know which method to use and when, with field-ready "choose this when" cards.

  • partial discharge testing bonus 2

    Bonus Resource #2

    Sensor Selection & PRPD Interpretation Guide

    Pick the right sensor per asset and read the pattern with confidence.

  • partial discharge testing bonus 3

    Bonus Resource #3

    Real-World Case Study Pack

    See PD testing on live assets: real detections, diagnoses, and the calls engineers made.

FAQS

Frequently Asked Questions

Confused about the process?
Our FAQ section provides clarity to help you move forward.

Do I need to complete Level 1 before Level 2?

We recommend it. Level 1 builds the fundamentals — how PD forms, detection theory, online vs offline testing — that Level 2's asset-specific diagnostics assume. If you already work with PD testing, you can move faster through Level 1, but it sets the foundation Level 2 builds on.

Can I enroll my whole team? Is there a corporate discount?

Yes. We offer team enrollment for groups of 5 or more — reach out to info@theelectricalguyacademy.com and we'll share the details.

Can I add my GST details when purchasing?

Yes. Just follow this quick guide: https://www.theelectricalguyacademy.com/help-center/add-gst-details-while-purchasing

What are CPD points?

CPD (Continuing Professional Development) points recognise the learning hours you invest in building your skills. Many engineering bodies and employers use them to track ongoing professional growth

Is this practical or just theory?

Practical. Every module is tied to real assets — switchgear, transformers, cables, rotating machines — with real-world case studies throughout, taught by working PD engineers.

Can I access the content anytime & anywhere?

Yes, you can access the content anytime & anywhere on laptop or mobile. Internet connection is required.

Is it live or recorded course?

This is a recorded course. You can access it as many times as you want.

Can I cancel my course purchase if I don’t like it? Will I get a refund?

Yes! You can cancel your course within 7 days of purchase if you don’t like it. We don’t want your money if you are unhappy with the course. Do check out our Return Policy for more details.

Whom do I contact in case of any issues or concerns?

If you need any assistance, please reach out to us via WhatsApp and your concerns will be addressed. You can also reach out to us via email - support@theelectricalguyacademy.com

Start Partial Discharge Testing Certification Pathway course today
Join TheElectricalGuy Academy Whatsapp Channel